Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
4
Rated voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
No
Type of control element
Push button
Overload release current setting
640.0 - 1600A
Motor drive integrated
No
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Motor drive optional
Yes
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072861R1 | E1.2N 1600 EKIP DIP LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
4
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
With switched-off indicator
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
Type of control element
Push button
Overload release current setting
640.0 .. 1600A
Motor drive integrated
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Motor drive optional
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
From same serie