Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
1600A
Suitable for DIN rail (top hat rail) mounting
No
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
640.0 - 1600A
Complete device with protection unit
Yes
DIN rail (top hat rail) mounting optional
No
Motor drive integrated
No
Motor drive optional
Yes
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
690 - 690V
Integrated earth fault protection
No
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072851R1 | E1.2C 1600 EKIP DIP LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
1600A
Suitable for DIN rail (top hat rail) mounting
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
640.0 .. 1600A
Complete device with protection unit
DIN rail (top hat rail) mounting optional
Motor drive integrated
Motor drive optional
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
690 .. 690V
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
From same serie