Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Overload release current setting
640.0 - 1600A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Device construction
Built-in device slide-in technique (withdrawable)
With under voltage release
No
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Type of control element
Push button
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Motor drive optional
Yes
Complete device with protection unit
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Degree of protection (IP)
IP30
Integrated earth fault protection
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072846R1 | E1.2B 1600 EKIP TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Overload release current setting
640.0 .. 1600A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Device construction
Built-in device slide-in technique (withdrawable)
With under voltage release
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Type of control element
Push button
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Motor drive optional
Complete device with protection unit
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Degree of protection (IP)
IP30
Integrated earth fault protection
From same serie