Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
750.0 - 12500A
Rated permanent current Iu
1250A
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Rated voltage
690 - 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
500.0 - 1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
With under voltage release
No
Type of control element
Push button
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072820R1 | E1.2C 1250 EKIP G HI-TOUCH LSIG

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
750.0 .. 12500A
Rated permanent current Iu
1250A
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Rated voltage
690 .. 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
500.0 .. 1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
With under voltage release
Type of control element
Push button
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Complete device with protection unit
Degree of protection (IP)
IP30
Motor drive integrated
From same serie