Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Type of control element
Push button
Rated permanent current Iu
1250A
With switched-off indicator
Yes
Rated voltage
690 - 690V
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
500.0 - 1250A
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Complete device with protection unit
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
From same serie
1SDA072811R1 | E1.2C 1250 EKIP DIP LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Type of control element
Push button
Rated permanent current Iu
1250A
With switched-off indicator
Rated voltage
690 .. 690V
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
500.0 .. 1250A
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Complete device with protection unit
Motor drive optional
Degree of protection (IP)
IP30
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
From same serie