Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
800A
Integrated earth fault protection
Yes
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
320.0 - 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Number of poles
4
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
With switched-off indicator
Yes
Complete device with protection unit
Yes
From same serie
1SDA072743R1 | E1.2N 800 EKIP DIP LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
800A
Integrated earth fault protection
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
320.0 .. 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Number of poles
4
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
With switched-off indicator
Complete device with protection unit
From same serie
We use cookies to enhance your experience.