Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive integrated
No
With switched-off indicator
Yes
Integrated earth fault protection
No
Rated permanent current Iu
800A
Rated voltage
690 - 690V
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
DIN rail (top hat rail) mounting optional
No
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Type of electrical connection of main circuit
Connection at separate chassis part
Type of control element
Push button
Overload release current setting
320.0 - 800A
Number of poles
4
Motor drive optional
Yes
Position of connection for main current circuit
Connection at separate chassis part
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Degree of protection (IP)
IP30
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Number of auxiliary contacts as normally open contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072742R1 | E1.2N 800 EKIP DIP LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive integrated
With switched-off indicator
Integrated earth fault protection
Rated permanent current Iu
800A
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Type of electrical connection of main circuit
Connection at separate chassis part
Type of control element
Push button
Overload release current setting
320.0 .. 800A
Number of poles
4
Motor drive optional
Position of connection for main current circuit
Connection at separate chassis part
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Degree of protection (IP)
IP30
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Number of auxiliary contacts as normally open contact
0