Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
630A
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
378.0 - 6300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range undelayed short-circuit release
945.0 - 9450A
With switched-off indicator
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Motor drive integrated
No
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
With under voltage release
No
Number of auxiliary contacts as change-over contact
4
Overload release current setting
252.0 - 630A
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Number of poles
4
Type of control element
Push button
Rated voltage
690 - 690V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072700R1 | E1.2C 630 EKIP G HI-TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
630A
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
378.0 .. 6300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range undelayed short-circuit release
945.0 .. 9450A
With switched-off indicator
Degree of protection (IP)
IP30
Complete device with protection unit
Motor drive integrated
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
With under voltage release
Number of auxiliary contacts as change-over contact
4
Overload release current setting
252.0 .. 630A
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Number of poles
4
Type of control element
Push button
Rated voltage
690 .. 690V
From same serie