Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
690 - 690V
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
945.0 - 9450A
Type of control element
Push button
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
Overload release current setting
252.0 - 630A
With switched-off indicator
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive integrated
No
Complete device with protection unit
Yes
Integrated earth fault protection
No
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072691R1 | E1.2C 630 EKIP DIP LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
690 .. 690V
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
945.0 .. 9450A
Type of control element
Push button
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
Overload release current setting
252.0 .. 630A
With switched-off indicator
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive integrated
Complete device with protection unit
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Degree of protection (IP)
IP30
From same serie