Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
6300A
Overload release current setting
2520.0 - 6300A
Rated voltage
690 - 690V
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Adjustment range undelayed short-circuit release
9450.0 - 94500A
Adjustment range short-term delayed short-circuit release
3780.0 - 63000A
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Number of poles
3
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
From same serie
1SDA072645R1 | E6.2H 6300 EKIP TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
6300A
Overload release current setting
2520.0 .. 6300A
Rated voltage
690 .. 690V
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Adjustment range undelayed short-circuit release
9450.0 .. 94500A
Adjustment range short-term delayed short-circuit release
3780.0 .. 63000A
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Number of poles
3
Complete device with protection unit
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
From same serie