Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1280.0 - 3200A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Rated permanent current Iu
3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Type of control element
Push button
Number of poles
3
With switched-off indicator
Yes
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Motor drive integrated
No
With under voltage release
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072530R1 | E4.2V 3200 EKIP G HI-TOUCH LSIG

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1280.0 .. 3200A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Rated permanent current Iu
3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Complete device with protection unit
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Type of control element
Push button
Number of poles
3
With switched-off indicator
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Motor drive integrated
With under voltage release