Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
3200A
DIN rail (top hat rail) mounting optional
No
Overload release current setting
1280.0 - 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Position of connection for main current circuit
Connection at separate chassis part
Rated voltage
690 - 690V
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
Yes
With switched-off indicator
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Type of control element
Push button
Number of poles
3
From same serie
1SDA072518R1 | E4.2H 3200 EKIP HI-TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
3200A
DIN rail (top hat rail) mounting optional
Overload release current setting
1280.0 .. 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Position of connection for main current circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
With switched-off indicator
Complete device with protection unit
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Type of control element
Push button
Number of poles
3
From same serie