Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Overload release current setting
1280.0 - 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
3200A
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
4800.0 - 48000A
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Complete device with protection unit
Yes
Number of poles
3
Motor drive integrated
No
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Degree of protection (IP)
IP30
From same serie
1SDA072515R1 | E4.2H 3200 EKIP TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Overload release current setting
1280.0 .. 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
3200A
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Complete device with protection unit
Number of poles
3
Motor drive integrated
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Motor drive optional
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Degree of protection (IP)
IP30
From same serie