Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
3200A
Overload release current setting
1280.0 - 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
With under voltage release
No
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
No
Motor drive optional
Yes
From same serie
1SDA072498R1 | E4.2N 3200 EKIP HI-TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
3200A
Overload release current setting
1280.0 .. 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
With under voltage release
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
Motor drive optional
From same serie