Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 - 690V
Rated permanent current Iu
2500A
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
1000.0 - 2500A
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
No
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072474R1 | E4.2V 2500 EKIP TOUCH LI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 .. 690V
Rated permanent current Iu
2500A
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
1000.0 .. 2500A
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
From same serie