Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2500A
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
1000.0 - 2500A
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Integrated earth fault protection
No
With switched-off indicator
Yes
With under voltage release
No
Complete device with protection unit
Yes
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Motor drive integrated
No
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072438R1 | E2.2H 2500 EKIP HI-TOUCH LSI 3P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2500A
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
1000.0 .. 2500A
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Integrated earth fault protection
With switched-off indicator
With under voltage release
Complete device with protection unit
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Motor drive integrated
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
From same serie