Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
2000A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Complete device with protection unit
Yes
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Motor drive integrated
No
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Yes
DIN rail (top hat rail) mounting optional
No
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Overload release current setting
800.0 - 2000A
Motor drive optional
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072409R1 | E2.2H 2000 EKIP HI-TOUCH LSIG 3P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
2000A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Complete device with protection unit
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Motor drive integrated
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Overload release current setting
800.0 .. 2000A
Motor drive optional
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
3000.0 .. 30000A