Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated permanent current Iu
2000A
Rated voltage
690 - 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Overload release current setting
800.0 - 2000A
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
With switched-off indicator
Yes
Number of poles
3
Motor drive integrated
No
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Motor drive optional
Yes
From same serie
1SDA072384R1 | E2.2N 2000 EKIP TOUCH LI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated permanent current Iu
2000A
Rated voltage
690 .. 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Overload release current setting
800.0 .. 2000A
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
With switched-off indicator
Number of poles
3
Motor drive integrated
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Motor drive optional
From same serie