Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1600A
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
640.0 - 1600A
Motor drive integrated
No
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 - 24000A
With switched-off indicator
Yes
Complete device with protection unit
Yes
Number of poles
3
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive optional
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Yes
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
From same serie
1SDA072337R1 | E2.2B 1600 EKIP G TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1600A
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
640.0 .. 1600A
Motor drive integrated
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
With switched-off indicator
Complete device with protection unit
Number of poles
3
DIN rail (top hat rail) mounting optional
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive optional
Type of electrical connection of main circuit
Connection at separate chassis part
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0