Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Integrated earth fault protection
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
500.0 - 1250A
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
1250A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Adjustment range short-term delayed short-circuit release
750.0 - 12500A
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Degree of protection (IP)
IP30
Number of poles
3
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive optional
Yes
From same serie
1SDA072325R1 | E2.2H 1250 EKIP TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Integrated earth fault protection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
500.0 .. 1250A
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
1250A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Adjustment range short-term delayed short-circuit release
750.0 .. 12500A
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Degree of protection (IP)
IP30
Number of poles
3
DIN rail (top hat rail) mounting optional
Type of control element
Push button
Complete device with protection unit
Motor drive optional
From same serie
We use cookies to enhance your experience.