Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Integrated earth fault protection
No
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range short-term delayed short-circuit release
750.0 - 12500A
Overload release current setting
500.0 - 1250A
Number of poles
3
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
With under voltage release
No
With switched-off indicator
Yes
Type of control element
Push button
Motor drive optional
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072318R1 | E2.2S 1250 EKIP HI-TOUCH LSI 3P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Integrated earth fault protection
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Suitable for DIN rail (top hat rail) mounting
Adjustment range short-term delayed short-circuit release
750.0 .. 12500A
Overload release current setting
500.0 .. 1250A
Number of poles
3
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
With under voltage release
With switched-off indicator
Type of control element
Push button
Motor drive optional
Motor drive integrated
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
From same serie