Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
1250A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Integrated earth fault protection
No
Type of control element
Push button
Number of poles
3
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
Yes
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated voltage
690 - 690V
Overload release current setting
500.0 - 1250A
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
From same serie
1SDA072311R1 | E2.2S 1250 EKIP DIP LI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
1250A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Integrated earth fault protection
Type of control element
Push button
Number of poles
3
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Degree of protection (IP)
IP30
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated voltage
690 .. 690V
Overload release current setting
500.0 .. 1250A
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
From same serie