Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated permanent current Iu
1250A
Integrated earth fault protection
No
Device construction
Built-in device slide-in technique (withdrawable)
With under voltage release
No
Number of poles
3
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Position of connection for main current circuit
Connection at separate chassis part
Overload release current setting
500.0 - 1250A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Type of control element
Push button
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP30
Motor drive optional
Yes
Motor drive integrated
No
Suitable for DIN rail (top hat rail) mounting
No
Complete device with protection unit
Yes
From same serie
1SDA072304R1 | E2.2N 1250 EKIP TOUCH LI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated permanent current Iu
1250A
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
With under voltage release
Number of poles
3
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Position of connection for main current circuit
Connection at separate chassis part
Overload release current setting
500.0 .. 1250A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Type of control element
Push button
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP30
Motor drive optional
Motor drive integrated
Suitable for DIN rail (top hat rail) mounting
Complete device with protection unit
From same serie