Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Overload release current setting
500.0 - 1250A
Adjustment range short-term delayed short-circuit release
750.0 - 12500A
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Rated permanent current Iu
1250A
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
With switched-off indicator
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
From same serie
1SDA072303R1 | E2.2N 1250 EKIP DIP LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Overload release current setting
500.0 .. 1250A
Adjustment range short-term delayed short-circuit release
750.0 .. 12500A
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Rated permanent current Iu
1250A
Suitable for DIN rail (top hat rail) mounting
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
With switched-off indicator
Motor drive optional
Degree of protection (IP)
IP30
Complete device with protection unit
From same serie