Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Overload release current setting
640.0 - 1600A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Rated voltage
690 - 690V
Number of poles
3
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
With under voltage release
No
Adjustment range undelayed short-circuit release
2400.0 - 24000A
With switched-off indicator
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Motor drive integrated
No
Device construction
Built-in device slide-in technique (withdrawable)
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072238R1 | E1.2N 1600 EKIP HI-TOUCH LSI 3P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Overload release current setting
640.0 .. 1600A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Rated voltage
690 .. 690V
Number of poles
3
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
With under voltage release
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
With switched-off indicator
Motor drive optional
Degree of protection (IP)
IP30
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Motor drive integrated
Device construction
Built-in device slide-in technique (withdrawable)
From same serie