Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
Yes
Complete device with protection unit
Yes
Motor drive integrated
No
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
640.0 - 1600A
Number of poles
3
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Number of auxiliary contacts as normally closed contact
0
From same serie
1SDA072236R1 | E1.2N 1600 EKIP TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Type of control element
Push button
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
Complete device with protection unit
Motor drive integrated
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
640.0 .. 1600A
Number of poles
3
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Number of auxiliary contacts as normally closed contact
0
From same serie