Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Overload release current setting
640.0 - 1600A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 - 24000A
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Complete device with protection unit
Yes
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Type of control element
Push button
Rated voltage
690 - 690V
Motor drive optional
Yes
Degree of protection (IP)
IP30
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072213R1 | E1.2B 1600 EKIP DIP LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Overload release current setting
640.0 .. 1600A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Complete device with protection unit
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Type of control element
Push button
Rated voltage
690 .. 690V
Motor drive optional
Degree of protection (IP)
IP30
Motor drive integrated
From same serie