Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
500.0 - 1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
DIN rail (top hat rail) mounting optional
No
Rated permanent current Iu
1250A
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range short-term delayed short-circuit release
750.0 - 12500A
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
With under voltage release
No
Number of poles
3
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Type of control element
Push button
Motor drive integrated
No
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072180R1 | E1.2B 1250 EKIP G HI-TOUCH LSIG

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
500.0 .. 1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
DIN rail (top hat rail) mounting optional
Rated permanent current Iu
1250A
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Adjustment range short-term delayed short-circuit release
750.0 .. 12500A
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
With under voltage release
Number of poles
3
Degree of protection (IP)
IP30
Complete device with protection unit
Type of control element
Push button
Motor drive integrated
Motor drive optional