Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
1000A
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
400.0 - 1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
With under voltage release
No
Degree of protection (IP)
IP30
Motor drive optional
Yes
Motor drive integrated
No
Type of control element
Push button
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Number of poles
3
From same serie
1SDA072146R1 | E1.2C 1000 EKIP TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
1000A
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
400.0 .. 1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
DIN rail (top hat rail) mounting optional
Complete device with protection unit
With under voltage release
Degree of protection (IP)
IP30
Motor drive optional
Motor drive integrated
Type of control element
Push button
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Number of poles
3