Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1000A
Rated voltage
690 - 690V
Integrated earth fault protection
Yes
Overload release current setting
400.0 - 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Yes
Complete device with protection unit
Yes
Type of control element
Push button
Motor drive integrated
No
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072137R1 | E1.2B 1000 EKIP G TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1000A
Rated voltage
690 .. 690V
Integrated earth fault protection
Overload release current setting
400.0 .. 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Complete device with protection unit
Type of control element
Push button
Motor drive integrated
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Degree of protection (IP)
IP30