Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Position of connection for main current circuit
Connection at separate chassis part
Rated permanent current Iu
800A
Integrated earth fault protection
Yes
Motor drive integrated
No
Number of poles
3
Rated voltage
690 - 690V
Motor drive optional
Yes
Overload release current setting
320.0 - 800A
From same serie
1SDA072117R1 | E1.2N 800 EKIP G TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Complete device with protection unit
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Position of connection for main current circuit
Connection at separate chassis part
Rated permanent current Iu
800A
Integrated earth fault protection
Motor drive integrated
Number of poles
3
Rated voltage
690 .. 690V
Motor drive optional
Overload release current setting
320.0 .. 800A