Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated voltage
690 - 690V
Overload release current setting
100.0 - 250A
Adjustment range short-term delayed short-circuit release
150.0 - 2500A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
375.0 - 3750A
Number of poles
3
Integrated earth fault protection
Yes
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive integrated
No
With under voltage release
No
Degree of protection (IP)
IP30
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072050R1 | E1.2N 250 EKIP G HI-TOUCH LSIG 3

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated voltage
690 .. 690V
Overload release current setting
100.0 .. 250A
Adjustment range short-term delayed short-circuit release
150.0 .. 2500A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
375.0 .. 3750A
Number of poles
3
Integrated earth fault protection
With switched-off indicator
DIN rail (top hat rail) mounting optional
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive integrated
With under voltage release
Degree of protection (IP)
IP30
Motor drive optional
From same serie