Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 - 690V
DIN rail (top hat rail) mounting optional
No
Overload release current setting
1600.0 - 4000A
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
4000A
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Motor drive optional
Yes
Complete device with protection unit
Yes
Type of control element
Push button
Position of connection for main current circuit
Back side
With switched-off indicator
Yes
Motor drive integrated
No
Integrated earth fault protection
Yes
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071967R1 | E6.2V/F 4000 EKIP G TOUCH LSIG 4P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 .. 690V
DIN rail (top hat rail) mounting optional
Overload release current setting
1600.0 .. 4000A
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
4000A
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Motor drive optional
Complete device with protection unit
Type of control element
Push button
Position of connection for main current circuit
Back side
With switched-off indicator
Motor drive integrated
Integrated earth fault protection
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
6000.0 .. 60000A