Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
4000A
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
Overload release current setting
1600.0 - 4000A
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Type of electrical connection of main circuit
Bolt connection
Rated voltage
690 - 690V
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Suitable for DIN rail (top hat rail) mounting
No
With under voltage release
No
Position of connection for main current circuit
Back side
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Type of control element
Push button
Motor drive integrated
No
Number of poles
4
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071862R1 | E6.2H 4000 EKIP DIP LSI 4P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
4000A
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Overload release current setting
1600.0 .. 4000A
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Type of electrical connection of main circuit
Bolt connection
Rated voltage
690 .. 690V
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Suitable for DIN rail (top hat rail) mounting
With under voltage release
Position of connection for main current circuit
Back side
Degree of protection (IP)
IP30
Complete device with protection unit
Type of control element
Push button
Motor drive integrated
Number of poles
4
Motor drive optional
From same serie