Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated permanent current Iu
4000A
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
1600.0 - 4000A
Complete device with protection unit
Yes
Motor drive optional
Yes
Integrated earth fault protection
Yes
Type of electrical connection of main circuit
Bolt connection
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Motor drive integrated
No
Number of poles
4
With switched-off indicator
Yes
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Degree of protection (IP)
IP30
Position of connection for main current circuit
Back side
Type of control element
Push button
Device construction
Built-in device fixed built-in technique
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071833R1 | E4.2S 4000 EKIP DIP LSIG 4P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated permanent current Iu
4000A
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
1600.0 .. 4000A
Complete device with protection unit
Motor drive optional
Integrated earth fault protection
Type of electrical connection of main circuit
Bolt connection
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Motor drive integrated
Number of poles
4
With switched-off indicator
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Degree of protection (IP)
IP30
Position of connection for main current circuit
Back side
Type of control element
Push button
Device construction
Built-in device fixed built-in technique
From same serie