Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
1280.0 - 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated voltage
690 - 690V
Rated permanent current Iu
3200A
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Back side
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of poles
4
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071774R1 | E4.2N 3200 EKIP TOUCH LI 4P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
1280.0 .. 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated voltage
690 .. 690V
Rated permanent current Iu
3200A
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Back side
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of poles
4
With switched-off indicator
DIN rail (top hat rail) mounting optional
Motor drive optional
Type of control element
Push button
Complete device with protection unit
Motor drive integrated
Degree of protection (IP)
IP30
From same serie
We use cookies to enhance your experience.