

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
Yes
Rated voltage
690 - 690V
Rated permanent current Iu
3200A
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Bolt connection
Position of connection for main current circuit
Back side
Complete device with protection unit
Yes
With switched-off indicator
Yes
Type of control element
Push button
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Motor drive integrated
No
Number of poles
4
Overload release current setting
1280.0 - 3200A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071773R1 | E4.2N 3200 EKIP DIP LSIG 4P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
Rated voltage
690 .. 690V
Rated permanent current Iu
3200A
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Bolt connection
Position of connection for main current circuit
Back side
Complete device with protection unit
With switched-off indicator
Type of control element
Push button
Motor drive optional
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Motor drive integrated
Number of poles
4
Overload release current setting
1280.0 .. 3200A
From same serie
We use cookies to enhance your experience.