Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Rated permanent current Iu
2000A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
No
Rated voltage
690 - 690V
Number of poles
4
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Back side
Motor drive optional
Yes
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Complete device with protection unit
Yes
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device fixed built-in technique
With switched-off indicator
Yes
Overload release current setting
800.0 - 2000A
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071665R1 | E2.2N 2000 EKIP TOUCH LSI 4P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Rated permanent current Iu
2000A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Rated voltage
690 .. 690V
Number of poles
4
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Back side
Motor drive optional
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Complete device with protection unit
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device fixed built-in technique
With switched-off indicator
Overload release current setting
800.0 .. 2000A
Degree of protection (IP)
IP30
From same serie