Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Overload release current setting
800.0 - 2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Rated voltage
690 - 690V
Number of poles
4
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Type of electrical connection of main circuit
Bolt connection
Motor drive integrated
No
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Type of control element
Push button
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Yes
Complete device with protection unit
Yes
Position of connection for main current circuit
Back side
Rated permanent current Iu
2000A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071663R1 | E2.2N 2000 EKIP DIP LSIG 4P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Overload release current setting
800.0 .. 2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Rated voltage
690 .. 690V
Number of poles
4
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Type of electrical connection of main circuit
Bolt connection
Motor drive integrated
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Type of control element
Push button
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Complete device with protection unit
Position of connection for main current circuit
Back side
Rated permanent current Iu
2000A
From same serie