Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
630A
Overload release current setting
252.0 - 630A
Integrated earth fault protection
Yes
Type of electrical connection of main circuit
Bolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Rated voltage
690 - 690V
With switched-off indicator
Yes
Adjustment range undelayed short-circuit release
945.0 - 9450A
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Type of control element
Push button
Degree of protection (IP)
IP30
Adjustment range short-term delayed short-circuit release
378.0 - 6300A
Motor drive optional
Yes
Device construction
Built-in device fixed built-in technique
Motor drive integrated
No
Complete device with protection unit
Yes
Position of connection for main current circuit
Back side
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071339R1 | E1.2B 630 EKIP HI-TOUCH LSIG 4P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
630A
Overload release current setting
252.0 .. 630A
Integrated earth fault protection
Type of electrical connection of main circuit
Bolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Rated voltage
690 .. 690V
With switched-off indicator
Adjustment range undelayed short-circuit release
945.0 .. 9450A
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Type of control element
Push button
Degree of protection (IP)
IP30
Adjustment range short-term delayed short-circuit release
378.0 .. 6300A
Motor drive optional
Device construction
Built-in device fixed built-in technique
Motor drive integrated
Complete device with protection unit
Position of connection for main current circuit
Back side
From same serie
We use cookies to enhance your experience.