Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
6300A
Adjustment range undelayed short-circuit release
9450.0 - 94500A
Type of electrical connection of main circuit
Bolt connection
Adjustment range short-term delayed short-circuit release
3780.0 - 63000A
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Overload release current setting
2520.0 - 6300A
Number of poles
3
Position of connection for main current circuit
Back side
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device fixed built-in technique
Motor drive integrated
No
Motor drive optional
Yes
Complete device with protection unit
Yes
Integrated earth fault protection
No
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071305R1 | E6.2V 6300 EKIP TOUCH LSI 3P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
6300A
Adjustment range undelayed short-circuit release
9450.0 .. 94500A
Type of electrical connection of main circuit
Bolt connection
Adjustment range short-term delayed short-circuit release
3780.0 .. 63000A
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Overload release current setting
2520.0 .. 6300A
Number of poles
3
Position of connection for main current circuit
Back side
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device fixed built-in technique
Motor drive integrated
Motor drive optional
Complete device with protection unit
Integrated earth fault protection
Degree of protection (IP)
IP30