Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
3200A
Overload release current setting
1280.0 - 3200A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Rated voltage
690 - 690V
Number of poles
3
Degree of protection (IP)
IP30
Motor drive optional
Yes
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of control element
Push button
Device construction
Built-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
With switched-off indicator
Yes
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
4
With under voltage release
No
Complete device with protection unit
Yes
Position of connection for main current circuit
Back side
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071142R1 | E4.2N 3200 EKIP DIP LSI 3P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
3200A
Overload release current setting
1280.0 .. 3200A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Rated voltage
690 .. 690V
Number of poles
3
Degree of protection (IP)
IP30
Motor drive optional
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of control element
Push button
Device construction
Built-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
With switched-off indicator
Motor drive integrated
Number of auxiliary contacts as change-over contact
4
With under voltage release
Complete device with protection unit
Position of connection for main current circuit
Back side