Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Overload release current setting
1000.0 - 2500A
Type of electrical connection of main circuit
Bolt connection
Suitable for DIN rail (top hat rail) mounting
No
With under voltage release
No
DIN rail (top hat rail) mounting optional
No
Number of poles
3
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
Integrated earth fault protection
Yes
Type of control element
Push button
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Position of connection for main current circuit
Back side
With switched-off indicator
Yes
Degree of protection (IP)
IP30
Motor drive integrated
No
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071090R1 | E2.2H 2500 EKIP G HI-TOUCH LSIG

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Overload release current setting
1000.0 .. 2500A
Type of electrical connection of main circuit
Bolt connection
Suitable for DIN rail (top hat rail) mounting
With under voltage release
DIN rail (top hat rail) mounting optional
Number of poles
3
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
Integrated earth fault protection
Type of control element
Push button
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Position of connection for main current circuit
Back side
With switched-off indicator
Degree of protection (IP)
IP30
Motor drive integrated
Complete device with protection unit
From same serie