Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
1000.0 - 2500A
Rated permanent current Iu
2500A
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device fixed built-in technique
Type of control element
Push button
With switched-off indicator
Yes
With under voltage release
No
Position of connection for main current circuit
Back side
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Motor drive optional
Yes
DIN rail (top hat rail) mounting optional
No
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
Number of poles
3
Type of electrical connection of main circuit
Bolt connection
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA071072R1 | E2.2S 2500 EKIP DIP LSI 3P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
1000.0 .. 2500A
Rated permanent current Iu
2500A
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device fixed built-in technique
Type of control element
Push button
With switched-off indicator
With under voltage release
Position of connection for main current circuit
Back side
Complete device with protection unit
Degree of protection (IP)
IP30
Motor drive optional
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
Number of poles
3
Type of electrical connection of main circuit
Bolt connection
Motor drive integrated
From same serie