Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Integrated earth fault protection
Yes
Type of electrical connection of main circuit
Bolt connection
Rated permanent current Iu
800A
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device fixed built-in technique
Overload release current setting
320.0 - 800A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Type of control element
Push button
Position of connection for main current circuit
Back side
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA070920R1 | E2.2H 800 EKIP G HI-TOUCH LSIG 3

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Integrated earth fault protection
Type of electrical connection of main circuit
Bolt connection
Rated permanent current Iu
800A
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Device construction
Built-in device fixed built-in technique
Overload release current setting
320.0 .. 800A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Type of control element
Push button
Position of connection for main current circuit
Back side
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Complete device with protection unit
Degree of protection (IP)
IP30
Motor drive optional
From same serie