Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
1600A
Overload release current setting
640.0 - 1600A
Type of electrical connection of main circuit
Bolt connection
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Back side
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
Motor drive optional
Yes
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Type of control element
Push button
Motor drive integrated
No
Degree of protection (IP)
IP30
Integrated earth fault protection
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA070875R1 | E1.2C 1600 EKIP TOUCH LSI 3P F F

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
1600A
Overload release current setting
640.0 .. 1600A
Type of electrical connection of main circuit
Bolt connection
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Back side
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Motor drive optional
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Type of control element
Push button
Motor drive integrated
Degree of protection (IP)
IP30
Integrated earth fault protection
From same serie