

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Device construction
Built-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
690 - 690V
Rated permanent current Iu
1000A
Overload release current setting
400.0 - 1000A
Integrated earth fault protection
Yes
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Bolt connection
With under voltage release
No
Position of connection for main current circuit
Back side
Number of poles
3
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Type of control element
Push button
With switched-off indicator
Yes
Motor drive optional
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA070800R1 | E1.2C 1000 EKIP G HI-TOUCH LSIG

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Device construction
Built-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
690 .. 690V
Rated permanent current Iu
1000A
Overload release current setting
400.0 .. 1000A
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Bolt connection
With under voltage release
Position of connection for main current circuit
Back side
Number of poles
3
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Type of control element
Push button
With switched-off indicator
Motor drive optional
Motor drive integrated
Degree of protection (IP)
IP30
Complete device with protection unit
From same serie
We use cookies to enhance your experience.