Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Overload release current setting
100.0 - 250A
Adjustment range undelayed short-circuit release
375.0 - 3750A
DIN rail (top hat rail) mounting optional
No
Rated voltage
690 - 690V
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Adjustment range short-term delayed short-circuit release
150.0 - 2500A
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Yes
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Motor drive integrated
No
Device construction
Built-in device fixed built-in technique
Type of control element
Push button
Motor drive optional
Yes
With switched-off indicator
Yes
Position of connection for main current circuit
Back side
Rated permanent current Iu
250A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA070693R1 | E1.2N 250 EKIP DIP LSIG 3P F F

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Overload release current setting
100.0 .. 250A
Adjustment range undelayed short-circuit release
375.0 .. 3750A
DIN rail (top hat rail) mounting optional
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Adjustment range short-term delayed short-circuit release
150.0 .. 2500A
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Motor drive integrated
Device construction
Built-in device fixed built-in technique
Type of control element
Push button
Motor drive optional
With switched-off indicator
Position of connection for main current circuit
Back side
Rated permanent current Iu
250A