Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Degree of protection (IP)
IP20
Type of control element
Toggle
Number of poles
2
Rated permanent current Iu
125A
Motor drive integrated
No
Rated voltage
240 - 550V
Motor drive optional
No
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Overload release current setting
90 - 90A
Adjustment range undelayed short-circuit release
900 - 900A
With under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
Adjustment range short-term delayed short-circuit release
- - -A
Position of connection for main current circuit
Front side
Complete device with protection unit
Yes
DIN rail (top hat rail) mounting optional
Yes
Integrated earth fault protection
No
Power loss
7W
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA066505R1 | A1N 125 TMF 90-900 2p F F

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Degree of protection (IP)
IP20
Type of control element
Toggle
Number of poles
2
Rated permanent current Iu
125A
Motor drive integrated
Rated voltage
240 .. 550V
Motor drive optional
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Overload release current setting
90 .. 90A
Adjustment range undelayed short-circuit release
900 .. 900A
With under voltage release
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
Adjustment range short-term delayed short-circuit release
- .. -A
Position of connection for main current circuit
Front side
Complete device with protection unit
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Power loss
7W
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release