Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Overload release current setting
1000.0 - 2500A
Rated permanent current Iu
2500A
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Rated voltage
1000 - 1000V
Number of poles
4
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Complete device with protection unit
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
With under voltage release
No
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA064720R1 | E3N 2500 PR123/DC IN=2500A 4P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Overload release current setting
1000.0 .. 2500A
Rated permanent current Iu
2500A
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Rated voltage
1000 .. 1000V
Number of poles
4
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Complete device with protection unit
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
With under voltage release
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
From same serie